Add to Favorites
Share

Wireless Bluetooth Multiparameter Patient Central Monitoring System

  • Description
Product Detail

    PRODUCT DESCRIPTION

    Multiparameter touch screen patient central monitoring system

    Landcom wireless bluetooth multiparameter patient central monitoring system model LD5 is a full-featured system that provides comprehensive patient monitoring and review, it is vital in operating and emergency room, as well as intensive and critical care settings. 

     

    FEATURES

    1.      12.1' color TFT LED screen supports display max. 8 waveforms. 

    2.      Visual On-display and integrated alarm light. 

    3.      Display mode: standard, large font, trend table, OxyCRG, full leads ECG.

    4.      Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection.

    5.      Drug calculation, titration table.

    6.      Suitable for monitoring adult, pediatric and neonatal patient.

    7.      Extended advance function: 2IBP, Depth of Anesthesia, EtCO2, Nellcor SpO2.

    8.      Anti-glare screen, Large capacity rechargeable battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature.

    9.      Dual IBP, Nellcor SpO2, MASIMO SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream).

    10. Thermal printer (50 mm).

    11. Pediatric / neonatal accessories: reusable NIBP cuffs & SpO2 probe; disposable NIBP cuff & SpO2 probe.

    12. Central Monitoring System.

    13. Touch Screen.

    14. Trolley/Wall Mount.

     

    PHYSICAL PROPERTIES

    Physical Specifications

    Dimension and weight

    Dimension

    340mm(W)*280mm(H)*130mm(D)

    Weight

    Standard configuration: 4 kg

    Operation environment

    Power requirements

    AC 100-240V, 50/60HZ, 60W

    Power

    90VA

    Temperature

    0-40?

    Humidity

    0-93% non-condensing

    Safety

    Meet the requirements of IEC60601   series

    Patient range

    Adult, neonate and pediatric   patients

    Performance Specification

    Display

    12.1’ (800 x 600 pixel) color TFT   LED screen

    Display mode

    Standard, big font, trend table,   full-lead ECG, Oxy CRG.

    Interface

    Parameter cable   interface

    AC power input socket

    Network interface

    Battery

    1 internal large capacity   rechargeable lithium battery

    Alarm indicator

    Visual on-display and   integrated alarm light

    Audible alarm

    Data storage

    108 hour trend graph

    168 hour trend table

    2 hour trend wave

    1024 alarm events

    Printer

    Built-in 50mm thermal   printer (option),

    3 traces, print speed   12.5mm/s & 25mm/s & 50mm/s

    Print width: 50mm

    Net working

    Support connection to central   monitoring station through LAN (TCP/IP) or wireless connection

    ECG

    Leads type

    3/5 lead : I, II, III, aVR, aVL,   aVF, V

    Sweep speed

    12.5mm/s, 25mm/s,50mm/s

    Gain selection

    ×0.25, ×0.5, ×1, ×2, Auto

    ECG waveform

    2 channels

    Operation mode

    Diagnostic, monitor, surgery

    Heart rate range

    0 - 350bpm

    Accuracy

    1bpm or ±1% whichever is great

    Alarm range

    Audible and visual alarm,   adjustable

    ST/ arrhythmia

    Real time S-T segment detection,   pace detection and arrhythmia analysis

    Protection

    Against electrosurgical   interference and defibrillation

    Respiration (RESP)

    Method

    Thoracic impedance

    Operation mode

    Auto


    Measurement range

    Adult: 0-120BrPM; neonatal   /pediatric: 0-150BrPM

    Apnea alarm

    Yes


    Alarm

    Yes, audible and visual alarm   ,alarm events recallable

    NIBP

    Method

    Automatic oscillometric

    Operation mode

    Manual / Automatic / STAT

    Auto measure time

    Adjustable

    Measurement unit

    mmHg / kPa  selectable

    Test interval

    1-480 minutes

    Measurement range

    Adult: 0-300 mmHg ;

    Child: 0-240 mmHg ;

    Infant: 0-150 mmHg

    Over-pressure protection

    Double safety protection

    Accuracy of blood pressure      measurement

    The mean error shall be   less than ± 5mmHg

    The standard deviation shall be less   than 8mmHG

    Resolution

    1 mmHg

    SPO2

    Measurement range

    0%-100%

    Resolution

    1%

    Accuracy

    ±2% (70-100%,   adult/pediatric, non-motion )

    ±3% (70-100%, neonate,   non-motion )

    ±3% (70-100%,   adult/pediatric/neonate, motion )

    0-69% unspecified

    Alarm range

    1-100%


    Pulse rate

    Pulse range:

    0-350bpm

    Accuracy

    ±3bpm(non-motion)

    ±5bpm(motion )

    Temperature (TEMP)

    TEMP range

    0-50?


    0.1 ?

    Accuracy

    ±0.1?    (excluding the sensor)

    Channel

    Dual-channel. provide T1;T2; ?T

    IBP

    Measurement range

    -50-360mmHg

    Channel

    2 channels

    Pressure transducer

    Sensitive :5 uV/V mmHg

    Impedance range :300-3000 O

    Pressure   names

    ART, PA, CVP,   RAP, LAP, ICP, P1, P2

    Alarm range

    -10-300 mmHg

    PR from IBP

    Range & Accuracy:

    25-200bpm  ±1bpm or ±1bpm which is greater

    201-350bpm ±2%

    Resolution

    1bpm

    Depth of Anesthesia (BIS)

    EEG sensitivity

    +/- 475µV

    Noise

    < 2uVp-p (1-150 Hz)

    CMRR

    > 100 dB

    Input impedance

    > 50mohm

    Sample rate

    1024 samples/s, 16 bits

    Index and display update

    0-100, filter 1-47 Hz, 1 sec.   display update

    EEG waveform

    ± 500 µV scaleable, filter 1–30   Hz, 3 sec. window length

    ESR

    0-100%

    EMG 0-100 arbitrary unit

    Curve and bar

    Index trend

    5 min and 60 min

    Digital output

    Wireless BT interface (RFCOMM) 10   meters range

    Alarms

    IoC high and low user selectable   limits

    Artifact rejection

    Automatic: user can disable.

    Sensor impedance range

    0 - 14kohm

    EtCO2 (Main-stream /   Side-stream )

    Measurement range

    0-150mmHg

    Accuracy

    ±2mmHg(0-40mmHg)

    ±5% of   reading(41-76mmHg)

    ±10% of reading (77-99mmHg)

    Resolution

    1mmHg

    Sampling rate

    70m1/min 100m1/min

    Sampling rate accuracy

    0.15 or 15m1/min

    Start-up time

     

    30 Sec. the module   enters the warming up status after the start up.1 minute later, it enters the   ready-to-measure status.

    Respiration rate

    3-150 rpm

    Respiration rate accuracy

    ±2BrPM (0-70BrPM)

    ±5BrPM (>70BrPM)

    Response time

    When measured with a   neonatal water trap and a 2.5 m-long neonatal sampling line:

    < 3.5 s @ 100 ml/min

    <4 s @ 70 ml/min

    When measured with an   adult water trap and a 2.5 m-long adult sampling line:

    <5.5 s @ 100 ml/min

    <7 s @ 70 ml/min

    Delay time

     

    When measured with a neonatal   water trap and a 2.5m-long neonatal sampling line:

    <3   s @ 100 ml/min

    <3.5 s @ 70 ml/min

    When measured with an   adult water trap and a 2.5m-long adult sampling line:

    <5 s @ 100 ml/min

    <6.5 s @ 70 ml/min

     

    WARRANTY PERIOD

    Products’ warranty period is 1 year from the goods delivery. 

     

    CERTIFICATES

    Our certificates are as below

    CERTIFICATES.png

     RELATED PRODUCTS

    RELATED PRODUCTS.png

    PACKING

    PACKING.png

     

    PAYMENT &SHIPMENT

    PAYMENT &SHIPMENT.png

     

    OUR ADVANTAGES

    1.      More than 20 years for manufacturing medical equipments.

    2.      Tsinghua technology forges the brand of Landcom, and Tsinghua University, Xi’an Jiao Tong University and Northwest  University are the backbones of Landcom R&D center.

    3.      Landcom joined Chinese medical instrument industry association and Chinese automobile industry association, and became one of the directors.

    4.      Landcom passed ISO9001, ISO13485, CE and WMI code.

     

    OUR SERVICES

    Reliability and the tenderest service are provided to clients.

    1.      Landcom supply value-added services to clients and to update the product software free for clients.

    2.      Landcom supply all-around response service & to reply clients’ demands in 24 hours.

    3.      Landcom have more than 20 experienced engineers service & solve problems for clients.

    4.      According to the official order quantity and actual situation of importing country, Landcom can build an after-sale service station in importing country to service clients.

     

    OUR COMMONWEAL AFFAIRES

    1.      Landcom donated 6 units FORD ambulance during the SARS crisis in 2003.

    2.      Landcom donated some computers to “xiwang” schools in 2003.

    3.      Lancom donated 2 units Mercedes Benz ambulances for Wenchuan earthquake disaster in 2008.

    4.      Landcom donated 2 units IVECO ambulances for Qinghai earthquake disaster in 2010.

    OUR COMMONWEAL AFFAIRES.png

     

    COMPANY INFORMATION

     

    Office building

    Office building.png

     

     

     

     

    Warehouse

    Warehouse.png

     

    Clients’ visit

    Clients’ visit.png

    Welcome to get superior and competitive price wireless bluetooth multiparameter patient central monitoring system for sale with Landcom Medical, a professional distributor and wholesaler in China. As one of the leading manufacturers, we have established reliable cooperative relationships with many companies.

Send your message to this supplier
To:  

Xi'an Landcom Digital Medical Sci-Tech Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :