3 Lead 24h Cardiac Holter System
-
Payment
-
Origin
China Mainland
-
Minimum Order
1
-
Packing
Pieces
- Contact Now Start Order
- Description
Product Detail
PRODUCT DESCRIPTION
3 lead 24h cardiac holter system
Landcom 3 lead 24h hour cardiac holter system LD-2301A With new developments in technology, cardiac diagnostics are no longer limited to standard Holter technology. Landcom has combined two of the most powerful diagnostic tools together to achieve and produce unmatched results.
Stepping into a new era of diagnostic-based medicine, Landocm has removed the need for multiple devices and combined them to achieve a truly comprehensive diagnostic technology to prevent, diagnose and treat the patient.
We bring Holter technology and ABPM to a new level of ambulatory monitoring with our Synchronized Holter/ABPM technology.
FEATURES
The most desirable, versatile Holter/ABPM device available
3 choices of programmable working modes: ambulatory ECG only (3-channel or 12-lead, full-disclosure), ABPM only or synchronized ambulatory ECG and ABPM.
Small and smart, the lightweight recorder is very comfortable to wear with little or no need to alter the patient's daily activities.
Highly integrated design saves space and improves the performance and reliability, adding to the recorder's durability, impact and shock-resistance.
With graphics displayed on LCD, you can view items such as current heart rate, total of beats, ECG of each lead, current or past blood pressure, next BP testing time, battery voltage, the cuff pressure value during inflating and deflating, and the number of beats in the process of BP testing. Visual icons and menu ensure easy access. ECG can be previewed to check electrode and lead connections to ensure high quality signal recognition.
Highly anti-jamming electrode connection, to assure universal electrode use while achieving high-quality signals.
With special amplifier and A/D convertor circuits, the recorder boasts a high fidelity of signal processing surpassing traditional standards, a 256Hz sampling frequency, a 1/1024 resolution as well as a clear and accurate display of ECG.
Reviewable blood pressure recording not only includes tabulated numerical data results, but also provides every artery pulsation waveform for possible review analysis.
Innovative intellectualized liquid control system ensures stable pressure and more accurate testing results. Quick inflation and linear deflation are completely imitates the auscultation process of physicians.
In the event of ECG abnormalities such as tachycardia, bradycardia and ST changes, the blood pressure testing will be initiated, thus better associating the two with each other. (Needs to be preset)
For a patient whose blood pressure jumps suddenly, the cuff will be automatically inflate to the proper pressure.
Wide dynamic range automatically adjusts to patients' blood pressures and pulsations.
Automatically monitors the battery and automatically stops in the event of a voltage insufficiency.
Large memory SD card is adopted to ensure 24-hour recording of comprehensive ECG and ABPM without compression while providing a solid compact size. The recorded data is preserved without damaged in the case of voltage shortage or battery accidentally being removed.
Conforms to the international standards with 5 or 7 electrodes for 3-channel, and 10 electrodes for 12-lead.
Double MCU, dual sensor, dual valve to ensure that patients will not be subject to excessive pressure or the pressure of a long time. In line with European standards EN 60601-2-30 for safety requirements on blood pressure equipment, it can guarantee security in any single fault condition:
? results in a failure of the normal pressure regulating means;
? prevents deflation of the cuff within the specified period;
? results in a failure of the normal cuff pressurization timing.
The wireless infrared interface features real-time monitoring, which not only ensures the proper utilization, but also enables the recorder to be used as a wireless ECG and blood pressure monitoring system.
Patient data and account information can be loaded into the recorder in advance to avoid possible mistakes, an appealing feature for multiple recorder facilities.
USB 2.0 technology allows quick transfer within seconds, enhancing efficiency.
Independent battery voltage recording channel records the 24-hour battery voltage curve that can externally estimate battery capacity and help analyze a possible breakdown.
Landcom products have unlimited upgrading potential, thus ensuring future hardware upgrading at minimum costs.
Effective Software technology
All the functions in the Landocm ambulatory ECG software are fully embedded.
Operator registration is required to prevent unauthorized access and ensure data security in accordance with virtually all hospital management requirements.
Data transfer in 30 seconds and automatic analysis in 10 seconds allows for quick accurate results without waiting.
Simultaneous observation of pressure-pulsation waveform and ECG waveform
Accurately identify QRS waveforms and automatically categorizing them into the four main morphology forms such as ventricular, supra-ventricular, normal, and artifact. Each QRS is classified and labeled to enhance analysis transparency and enable easy use of the software.
Instead of the repetitive one-by-one processing, the software's innovative second order analysis employs automatic batch processing. This revolution in technology is leaps and bounds ahead of the competition and produces vastly superior diagnostic results.
The recorded reviewable pressure-pulsation waveforms identifies proper blood pressure testing, thus results are accurate and effective. In the event of false analysis due to interferences, the real blood pressure is available with the help of human interaction. False analysis due to serious interferences can be deleted to ensure the accuracy and reliability of the patient report.
Flexible and streamline editing of QRS waves, such as by unit, by line, by row or all at once. Multiple customizations are available to provide any user the confidence of managing the analysis capability.
Adjustable scanning criteria allow you to set parameters for specific patient types or research protocols.
Multiple tools enable you to edit individual ECG. You can edit standard ECG by insertion, deletion or redefinition. Keyboard and mouse driven interface allows quick comprehensive editing
On-screen calipers allow quick and precise measurements.
Comprehensive ST Report with each ST episode, including deviation, slope, duration and heart rate at onset/offset.
Full-featured analyses cover not only the basic patterns of arrhythmia and ST analysis, but also time and frequency domains and nonlinear analysis of HRV, pacemaker analysis as well as blood pressure variability analysis.
The operation interface combines both mouse buttons with the keyboard, ensuring efficiency based on experience.
The software enables multiple ECG scanning styles, including the standard, the "mini" format and page scan. In mini format and page scan, different colors are used to indicate normal, artifact, ventricular, supra-ventricular and paced.
Abundant trend graphs, statistics and category-specific histograms.
Customizable physician comments can be added on the first page before printing
The operator can set the interface colors and styles.
Print reports with your institution's logo.
Logical on-screen command buttons and easy-to-follow icons.
Queuing in analysis and printing tasks makes simultaneous processing possible. While you are editing or reviewing files in the foreground, the system software is analyzing or printing reports automatically.
The system can automatically generate various typical diagnostic strips with classification, time of occurrence, heart rate and beat annotations. You can conveniently choose to print any event or insert additional ECG-strip information.
Specifications
ECG : | ||
Detecting channel | 3-channel ECG | Independent pacemaker detection |
Battery voltage recording channel | ||
Patient Input configuration | 5 or 7 electrodes | |
Input dynamic range | ±5 mV ECG, ±300 mV offset voltage | |
Input impedance | > 10 MO | |
Common mode rejection | =75dB | |
Gain accuracy | Maximum amplitude error = 10% | |
Gain stability The change | = 3 % over a 24 h period | |
System noise | < 50 µVp-v | |
Multi-channel crosstalk | =0.2 mVp-v | |
Frequency response | 0.05 Hz ~ 40 Hz (±3 dB) | |
Minimum feature size | 50 µVp-v | |
Timing accuracy | The overall error during 24 h = 30 s | |
Sample Rate | 256 Hz/channel | |
2048 Hz/channel (pacemaker detection) | ||
A/D resolution | 10 bits | |
Blood pressure: | ||
Method of measurement | Oscillometric method
| |
Indicating range | 0 ~ 300 mmHg | |
Recording range | Systolic 50 ~ 260 mmHg Diastolic 30 ~ 180 mmHg | |
Pressure precision | =3 mmHg | |
All-purpose: | ||
Recording time | 24 hours | |
Data transfer | Full-disclosure transfer USB card reader Pre-set & real-time transfer Wireless infrared | |
Storage medium | SD card | |
Memory size | 256 MB or more | |
Batteries | 4 x AA size alkaline batteries | |
Dimensions | 124 x 68 x 31(mm3) | |
Weight | 180 g (excluding batteries) | |
Safety type | Type B equipment with internal battery continuous operation | |
PC minimum requirements | Pentium III 500 MHz or higher 1024 x 768 resolution | |
System requirements | Windows 9x/2000/XP/Vista |
WARRANTY PERIOD
Products’ warranty period is 1 year from the goods delivery.
CERTIFICATES
Our certificates are as below
RELATED PRODUCTS
PACKING
PAYMENT &SHIPMENT
OUR ADVANTAGES
1.More than 20 years for manufacturing medical equipments.
2.Tsinghua technology forges the brand of Landcom, and Tsinghua University, Xi’an Jiao Tong University and
Northwest University are the backbones of Landcom R&D center.
3.Landcom joined Chinese medical instrument industry association and Chinese automobile industry association,
and became one of the directors.
4.Landcom passed ISO9001, ISO13485, CE and WMI code.
OUR SERVICES
Reliability and the tenderest service are provided to clients.
1.Landcom supply value-added services to clients and to update the product software free for clients.
2.Landcom supply all-around response service & to reply clients’ demands in 24 hours.
3.Landcom have more than 20 experienced engineers service & solve problems for clients.
4.According to the official order quantity and actual situation of importing country, Landcom can build an
after-sale service station in importing country to service clients.
OUR COMMONWEAL AFFAIRES
1.Landcom donated 6 units FORD ambulance during the SARS crisis in 2003.
2.Landcom donated some computers to “xiwang” schools in 2003.
3.Lancom donated 2 units Mercedes Benz ambulances for Wenchuan earthquake disaster in 2008.
4.Landcom donated 2 units IVECO ambulances for Qinghai earthquake disaster in 2010.
COMPANY INFORMATION
Office building
Warehouse
Clients’ visit
Welcome to get superior and competitive price 3 lead 24h cardiac holter system for sale with Landcom Medical, a professional distributor and wholesaler in China. As one of the leading manufacturers, we have established reliable cooperative relationships with many companies.
- 3 Lead 24 Hour Cardiac Holter System 1 Pieces / (Min. Order)
- Cardiac Exercise Stress Test System Equipment with Bicycle 1 Pieces / (Min. Order)
- PC Based Cardiac Exercise ECG Stress Test System Equipment with Treadmill 1 Pieces / (Min. Order)
- OLED Display Maternal Fetal Monitor Fetal Heart Monitor 1 Pieces / (Min. Order)
- Wireless Bluetooth Portable Maternal/fetal Monitor Fetal Heart Monitor 1 Pieces / (Min. Order)
- Portable Multiparameter ICU Vital Signs Monitor 1 Pieces / (Min. Order)
- Digital Veterinary Patient Monitor Veterinary Central Patient Monitoring System 1 Pieces / (Min. Order)
- Digital Portable Central Monitoring System Central Monitoring Device 1 Pieces / (Min. Order)
- Wireless Bluetooth Multiparameter Patient Central Monitoring System 1 Pieces / (Min. Order)
- 12 Lead 24h Cardiac Holter System 1 Pieces / (Min. Order)
- 12 Lead 24 Hour Cardiac Holter System 1 Pieces / (Min. Order)
- 3 Lead 24 Hour Cardiac Holter System 1 Pieces / (Min. Order)